Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
1.
Comput Biol Med ; 174: 108401, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38603897

RESUMO

Incorporating detailed muscle architecture aspects into computational models can enable researchers to gain deeper insights into the complexity of muscle function, movement, and performance. In this study, we employed histological, multiphoton image processing, and finite element method techniques to characterise the mechanical dependency on the architectural behaviour of supraspinatus and infraspinatus mouse muscles. While mechanical tests revealed a stiffer passive behaviour in the supraspinatus muscle, the collagen content was found to be two times higher in the infraspinatus. This effect was unveiled by analysing the alignment of fibres during muscle stretch with the 3D models and the parameters obtained in the fitting. Therefore, a strong dependence of muscle behaviour, both active and passive, was found on fibre orientation rather than collagen content.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38223952

RESUMO

Summary: Background. Asthma control can be influenced by several factors, including obstructive sleep apnea (OSA). The literature reports variable prevalence and magnitude of OSA impact on asthma outcomes. The aim of our study is to analyze the frequency of high-risk for OSA in asthma patients and its impact on disease severity and control. Methods. We conducted a cross-sectional study at an Allergy Department with adult asthma patients recruited while undergoing routine lung function tests. Data on sex, age, body mass index, allergen sensitization, smoking habits, risk of OSA (using the Berlin questionnaire), rhinitis control (through CARAT), asthma severity (based on GINA 2023), asthma control (using the ACT), adherence to asthma treatment (through Treatment Adherence Measure) and pulmonary function test results were collected. Results. We included 216 patients, predominantly women (70.4%), with a median (P25-P75) age of 29.0 (21.0-45.0) years, of whom 28.2% were on GINA treatment levels 4-5. In 75.5% of cases asthma was controlled. High-risk for OSA was identified in 21.8% of patients. Asthma patients with high-risk for OSA were more likely to have uncontrolled [(47.8%; n = 22) vs (15.8%; n = 26); p less than 0.001] and more severe disease [(44.7%; n = 21) vs (23.7%; n = 40), p = 0.006]. In multivariable analysis, high-risk for OSA (OR 2.81 [95%CI 1.1.28-6.17], p = 0.010), sex (women) (OR 5.21 [95% CI 1.70-15.96], p = 0.004), uncontrolled rhinitis (OR 3.65 [95%CI 1.38-9.64], p = 0.009) and GINA asthma treatment steps 4-5 (OR 2.46 [95%CI 1.15-5.26], p = 0.020) were associated with uncontrolled asthma. Conclusions. It is crucial to actively investigate OSA, especially in patients with uncontrolled and more severe forms of asthma.

4.
Int J Tuberc Lung Dis ; 27(10): 729-741, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37749839

RESUMO

BACKGROUND: The aim of these clinical standards is to provide guidance on 'best practice' care for the diagnosis, treatment and prevention of post-COVID-19 lung disease.METHODS: A panel of international experts representing scientific societies, associations and groups active in post-COVID-19 lung disease was identified; 45 completed a Delphi process. A 5-point Likert scale indicated level of agreement with the draft standards. The final version was approved by consensus (with 100% agreement).RESULTS: Four clinical standards were agreed for patients with a previous history of COVID-19: Standard 1, Patients with sequelae not explained by an alternative diagnosis should be evaluated for possible post-COVID-19 lung disease; Standard 2, Patients with lung function impairment, reduced exercise tolerance, reduced quality of life (QoL) or other relevant signs or ongoing symptoms ≥4 weeks after the onset of first symptoms should be evaluated for treatment and pulmonary rehabilitation (PR); Standard 3, The PR programme should be based on feasibility, effectiveness and cost-effectiveness criteria, organised according to local health services and tailored to an individual patient's needs; and Standard 4, Each patient undergoing and completing PR should be evaluated to determine its effectiveness and have access to a counselling/health education session.CONCLUSION: This is the first consensus-based set of clinical standards for the diagnosis, treatment and prevention of post-COVID-19 lung disease. Our aim is to improve patient care and QoL by guiding clinicians, programme managers and public health officers in planning and implementing a PR programme to manage post-COVID-19 lung disease.


Assuntos
COVID-19 , Qualidade de Vida , Humanos , Progressão da Doença , Escolaridade , Exercício Físico , Teste para COVID-19
5.
Med. intensiva (Madr., Ed. impr.) ; 47(8): 445-453, ago. 2023.
Artigo em Inglês | IBECS | ID: ibc-223940

RESUMO

Objective To compare adherence to protective mechanical ventilation (MV) parametersin patients with acute respiratory distress syndrome (ARDS) caused by COVID-19 with patients with ARDS from other etiologies. Design Multiple prospective cohort study. Setting: Two Brazilian cohorts of ARDS patients were evaluated. One with COVID-19 patients admitted to two Brazilian intensive care units (ICUs) in 2020 and 2021 (C-ARDS, n=282), the other with ARDS-patients from other etiologies admitted to 37 Brazilian ICUs in 2016 (NC-ARDS, n=120). Patients: ARDS patients under MV. Interventions: None. Main variables of interest: Adherence to protective MV (tidal volume ≤8mL/kg PBW; plateau pressure ≤30cmH2O; and driving pressure ≤15cmH2O), adherence to each individual component of the protective MV, and the association between protective MV and mortality. Results Adherence to protective MV was higher in C-ARDS than in NC-ARDS patients (65.8% vs. 50.0%, p=0.005), mainly due to a higher adherence to driving pressure ≤15cmH2O (75.0% vs. 62.4%, p=0.02). Multivariable logistic regression showed that the C-ARDS cohort was independently associated with adherence to protective MV. Among the components of the protective MV, only limiting driving pressure was independently associated with lower ICU mortality. Conclusions Higher adherence to protective MV in patients with C-ARDS was secondary to higher adherence to limiting driving pressure. Additionally, lower driving pressure was independently associated with lower ICU mortality, which suggests that limiting exposure to driving pressure may improve survival in these patients (AU)


Objetivo Comparar la adhesión a la ventilación mecánica (VM) protectora en pacientes con síndrome de dificultad respiratoria aguda (SDRA) causada por COVID-19 con pacientes con SDRA de otras etiologías. Diseño Estudio de cohorte prospectivo. Âmbito: Se evaluaron dos cohortes de pacientes con SDRA: 1.pacientes con COVID-19 ingresados en dos unidades de cuidados intensivos (UCI) brasileñas en 2020 y 2021 (C-ARDS, n=282); 2.pacientes con SDRA de otras etiologías ingresados en 37 UCI brasileñas en 2016 (NC-ARDS, n=120). Pacientes: Pacientes con SDRA bajo VM invasiva. Intervenciones: No. Variables de interés principals: Adhesión a la VM protectora (volumen tidal ≤8mL/kg; presión de meseta ≤30cmH2O; y presión de distensión [PD] ≤15cmH2O), adhesión a cada componente individual de la VM protectora, y la asociación entre la VM protectora y la mortalidad. Resultados La adhesión a la VM protectora fue mayor en la cohorte C-ARDS que en la NC-ARDS (65,8% vs. 50,0%, p=0,005), principalmente debido a mayor adhesión a la PD≤15cmH2O (75,0% vs. 62,4%, p=0,02). La regresión logística multivariable mostró que la cohorte C-ARDS se asoció de forma independiente con la adhesión a la VM protectora. Entre los componentes de la VM protectora, sólo la limitación de la PD se asoció de forma independiente con menor mortalidad en la UCI. Conclusión La mayor adhesión a la VM protectora en los pacientes con C-ARDS fue secundaria a la mayor adhesión a limitación da PD. Además, una menor PD se asoció de forma independiente a menor mortalidad en la UCI, lo que sugiere que limitar la exposición a altas PD puede mejorar la supervivencia en estos pacientes (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , Infecções por Coronavirus/complicações , Respiração Artificial , Estudos Prospectivos , Estudos de Coortes , Volume de Ventilação Pulmonar
6.
Pulmonology ; 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37230882

RESUMO

OBJECTIVE: To quantify the impact of different air pollutants on respiratory health based on robust estimates based on international data and to summarise the evidence of associations between indoor exposure to those pollutants and respiratory morbidity in the Portuguese population. RESULTS: Several systematic reviews and meta-analyses (MA) at the world level demonstrate the impact of indoor air quality on respiratory health, with indoor particulate matter and gasses exerting a significant effect on the airways. Volatile organic compounds (VOC) have been related to asthma and lung cancer. However, only meta-analyses on biomass use allowed documentation of long-term respiratory effects. While early publications concerning Portuguese-based populations mainly focused on indoor exposure to environmental tobacco smoke, later studies relocated the attention to relevant exposure environments, such as day care buildings, schools, residences and nursing homes. Looking at the pooled effects from the reviewed studies, high levels of carbon dioxide and particulate matter in Portuguese buildings were significantly associated with asthma and wheezing, with VOC and fungi showing a similar effect in some instances. CONCLUSIONS: Despite the significant reduction of indoor air pollution effects after the 2008 indoor smoking prohibition in public buildings, studies show that several indoor air parameters are still significantly associated with respiratory health in Portugal. The country shares the worldwide necessity of standardisation of methods and contextual data to increase the reach of epidemiological studies on household air pollution, allowing a weighted evaluation of interventions and policies focused on reducing the associated respiratory morbidity.

8.
ACS Appl Mater Interfaces ; 15(8): 11234-11243, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36802478

RESUMO

One of the essential issues in modern advanced materials science is to design and manufacture flexible devices, in particular in the framework of the Internet of Things (IoT), to improve integration into applications. An antenna is an essential component of wireless communication modules and, in addition to flexibility, compact dimensions, printability, low cost, and environmentally friendlier production strategies, also represent relevant functional challenges. Concerning the antenna's performance, the optimization of the reflection coefficient and maximum range remain the key goals. In this context, this work reports on screen-printed paper@Ag-based antennas and optimizes their functional properties, with improvements in the reflection coefficient (S11) from -8 to -56 dB and maximum transmission range from 208 to 256 m, with the introduction of a PVA-Fe3O4@Ag magnetoactive layer into the antenna's structure. The incorporated magnetic nanostructures allow the optimization of the functional features of antennas with possible applications ranging from broadband arrays to portable wireless devices. In parallel, the use of printing technologies and sustainable materials represents a step toward more sustainable electronics.

9.
Med Intensiva (Engl Ed) ; 47(8): 445-453, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36813658

RESUMO

OBJECTIVE: To compare adherence to protective mechanical ventilation (MV) parameters in patients with acute respiratory distress syndrome (ARDS) caused by COVID-19 with patients with ARDS from other etiologies. DESIGN: Multiple prospective cohort study. SETTING: Two Brazilian cohorts of ARDS patients were evaluated. One with COVID-19 patients admitted to two Brazilian intensive care units (ICUs) in 2020 and 2021 (C-ARDS, n=282), the other with ARDS-patients from other etiologies admitted to 37 Brazilian ICUs in 2016 (NC-ARDS, n=120). PATIENTS: ARDS patients under MV. INTERVENTIONS: None. MAIN VARIABLES OF INTEREST: Adherence to protective MV (tidal volume ≤8mL/kg PBW; plateau pressure ≤30cmH2O; and driving pressure ≤15cmH2O), adherence to each individual component of the protective MV, and the association between protective MV and mortality. RESULTS: Adherence to protective MV was higher in C-ARDS than in NC-ARDS patients (65.8% vs. 50.0%, p=0.005), mainly due to a higher adherence to driving pressure ≤15cmH2O (75.0% vs. 62.4%, p=0.02). Multivariable logistic regression showed that the C-ARDS cohort was independently associated with adherence to protective MV. Among the components of the protective MV, only limiting driving pressure was independently associated with lower ICU mortality. CONCLUSIONS: Higher adherence to protective MV in patients with C-ARDS was secondary to higher adherence to limiting driving pressure. Additionally, lower driving pressure was independently associated with lower ICU mortality, which suggests that limiting exposure to driving pressure may improve survival in these patients.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial/efeitos adversos , Estudos Prospectivos , COVID-19/complicações , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar
10.
Brain Impair ; 24(3): 721-731, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38167367

RESUMO

OBJECTIVE: Decompressive craniectomy is part of the acute management of several neurosurgical illnesses, and is commonly followed by cranioplasty. Data are still scarce on the functional and cognitive outcomes following cranioplasty. We aim to evaluate these outcomes in patients who underwent cranioplasty following traumatic brain injury (TBI) or stroke. METHODS: In this prospective cohort, we assessed 1-month and 6-month neuropsychological and functional outcomes in TBI and stroke patients who underwent cranioplasty at a Brazilian tertiary center. The primary outcome was the change in the Digits Test at 1 and 6 months after cranioplasty. Repeated measures general linear models were employed to assess the patients' evolution and interactions with baseline characteristics. Effect size was estimated by the partial η2. RESULTS: A total of 20 TBI and 14 stroke patients were included (mean age 42 ± 14 years; 52.9% male; average schooling 9.5 ± 3.8 years; 91.2% right-handed). We found significant improvements in the Digits Tests up to 6 months after cranioplasty (p = 0.004, partial η2 = 0.183), as well as in attention, episodic memory, verbal fluency, working memory, inhibitory control, visuoconstructive and visuospatial abilities (partial η2 0.106-0.305). We found no interaction between the cranioplasty effect and age, sex or schooling. Patients submitted to cranioplasty earlier (<1 year) after injury had better outcomes. CONCLUSION: Cognitive and functional outcomes improved after cranioplasty following decompressive craniectomy for stroke or TBI. This effect was consistent regardless of age, sex, or education level and persisted after 6 months. Some degree of spontaneous improvement might have contributed to the results.


Assuntos
Lesões Encefálicas Traumáticas , Craniectomia Descompressiva , Acidente Vascular Cerebral , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Lactente , Feminino , Estudos de Coortes , Estudos Prospectivos , Resultado do Tratamento , Craniectomia Descompressiva/efeitos adversos , Lesões Encefálicas Traumáticas/cirurgia , Acidente Vascular Cerebral/cirurgia
11.
ACS Sustain Chem Eng ; 10(13): 4122-4132, 2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-36573099

RESUMO

Polymer-based magnetoelectric (ME) nanocomposites are an enabling material technology for a wide range of applications in the area of digitalization strategies. Due to its highest piezoelectric response among polymers, poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE) is the piezoelectric matrix most used in polymer-based ME materials with over 80% of the total reports, with the resulting composites typically processed from solutions with N,N-dimethylformamide (DMF), a toxic solvent. Nevertheless, environmentally friendlier approaches and sustainable technologies are increasingly being required. This work demonstrates that P(VDF-TrFE)/Co2Fe2O4 nanocomposites can be successfully prepared from solution using three different environmentally friendlier solvents: dimethyl sulfoxide (DMSO), N,N'-dimethylpropyleneurea (DMPU), and triethyl phosphate (TEP) with different dipole moments. It is shown that the prepared composite films, with a maximum ME voltage coefficient of 35 mV cm-1 Oe-1 and a maximum sensitivity of 2.2 mV T-1, are suitable for applications, highlighting the path for a new generation of more sustainable ME sensors.

12.
Chemosphere ; 307(Pt 2): 135922, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35940413

RESUMO

Natural or industrial hexavalent chromium water pollution continues to be a worldwide unresolved threat. Today, there is intense research on new active and cost-effective sorbents for Cr(VI), but most still exhibit a critical limitation: their powdered nature makes their recovery from water cost and energy consuming. In this work, Al(OH)3, MIL-88-B(Fe), and UiO-66-NH2 Cr(VI) sorbents were immobilized into a poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) polymeric substrate to develop an easily reactivable and reusable water filtering technology. The immobilization of the sorbents into the PVDF-HFP porous matrix modified the macro and meso-porous structure of the polymeric matrix, tuning in parallel its wettability. Although a partial blocking of the Cr(VI) adsorptive capacity was observed for of Al(OH)3 and MIL-88-B(Fe) when immobilized into composite membranes, PVDF-HFP/UiO-66-NH2 filter (i) exceeded the full capacity of the non-immobilized sorbent to trap Cr(VI), (ii) could be reactivated and reusable, and (iii) it was fully functional when applied in real water effluents.


Assuntos
Poluentes Químicos da Água , Água , Adsorção , Cromo/análise , Polímeros de Fluorcarboneto , Estruturas Metalorgânicas , Ácidos Ftálicos , Polivinil , Poluentes Químicos da Água/análise
13.
Chemosphere ; 293: 133548, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34999100

RESUMO

This work focuses on the combination of multifunctional photocatalytic and adsorbent materials in a unique polymeric membrane. For this purpose, Au/TiO2 and Y2(CO3)3 nanoparticles were immobilised onto a poly (vinylidene fluoride-hexafluoropropylene), (PVDF-HFP) membrane, and the physical-chemical characterisation of these materials was performed, as well as pollutant removal efficiency. An efficient TiO2 functionalisation with gold nanoparticles was achieved, endowing these particles with the capability to absorb visible radiation absorption. A favourable porous structure was obtained for the membranes, with an average pore size of 4 µm, and the nanoparticles immobilisation did not alter the chemical properties of the polymeric membrane. The produced hybrid materials, including both the Au/TiO2 and Y2(CO3)3 nanoparticles, presented an efficiency of 57% in the degradation of norfloxacin (5 mg/L) under ultraviolet radiation for 120 min, 80% under visible radiation for 300 min, and 58% in arsenic adsorption for 240 min. These membranes represent a new multifunctional platform for removing several pollutants, which may allow their incorporation in more efficient and less energy-consuming water treatment processes favouring its application, even in low energy resources countries.


Assuntos
Ouro , Nanopartículas Metálicas , Adsorção , Titânio/química , Raios Ultravioleta
16.
Mater Horiz ; 8(10): 2654-2684, 2021 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-34617551

RESUMO

The potential implications/applications of printing technologies are being recognized worldwide across different disciplines and industries. Printed magnetoactive smart materials, whose physical properties can be changed by the application of external magnetic fields, are an exclusive class of smart materials that are highly valuable due to their magnetically activated smart and/or multifunctional response. Such smart behavior allows, among others, high speed and low-cost wireless activation, fast response, and high controllability with no relevant limitations in design, shape, or dimensions. Nevertheless, the printing of magnetoactive materials is still in its infancy, and the design apparatus, the material set, and the fabrication procedures are far from their optimum features. Thus, this review presents the main concepts that allow interconnecting printing technologies with magnetoactive materials by discussing the advantages and disadvantages of this joint field, trying to highlight the scientific obstacles that still limit a wider application of these materials nowadays. Additionally, it discusses how these limitations could be overcome, together with an outlook of the remaining challenges in the emerging digitalization, Internet of Things, and Industry 4.0 paradigms. Finally, as magnetoactive materials will play a leading role in energy generation and management, the magnetic-based Green Deal is also addressed.

17.
J Investig Allergol Clin Immunol ; 31(6): 471-480, 2021 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-32694095

RESUMO

BACKGROUND AND OBJECTIVES: Data on risk factors for uncontrolled asthma in preschool children are controversial. Objective: This study aims to explore the association between clinical and functional parameters and the lack of asthma control in preschool children. METHODS: Children aged 3-5 years with asthma and healthy controls were recruited. A questionnaire was used to identify potential risk factors for uncontrolled asthma, as defined by the Global INitiative for Asthma criteria. Lung function and bronchial reversibility were evaluated through impulse oscillometry and spirometry. Adjusted odds ratios were estimated based on multivariable generalized additive regression models. The discriminative ability of the models was measured by the area under the receiver operating characteristic curve (AUC). RESULTS: The study population comprised 121 children (107 with asthma and 14 healthy controls). Fifty-three patients (50%) had uncontrolled asthma. After adjustment, the variables associated with an increased risk of lack of control were as follows: "More than 3 flare-ups in the last 12 months", "Moderate to severe rhinitis", and "Relative variation in postbronchodilator FVC and FEV1". The AUC of the final models that included variation in FVC or FEV1 were 0.82 and 0.81, respectively. The R5-20, R5-20%, and AX z-score values of the healthy group were lower than those of children with asthma. CONCLUSION: In preschool children, clinical and functional parameters are associated with uncontrolled asthma. More studies are needed to confirm the usefulness of impulse oscillometry.


Assuntos
Asma , Asma/diagnóstico , Asma/epidemiologia , Pré-Escolar , Volume Expiratório Forçado , Humanos , Razão de Chances , Oscilometria , Testes de Função Respiratória , Espirometria
18.
Chemosphere ; 262: 128300, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33182084

RESUMO

Metronidazole (MNZ) is a recalcitrant antibiotic with toxic and carcinogenic effects in aquatic environments. In this work, Fe5(PO4)4(OH)3·2H2O (giniite) particles were synthesised with three different alkaline cations (Li+, Na+ and K+) and used as Fenton catalysts for MNZ removal. It is shown that the addition of different cations during the hydrothermal synthesis process promote different morphologies from asterisk-like to flower-like and branches-like, maintaining the crystalline structure of pure giniite. The photo-Fenton activity of these particles was then evaluated through the degradation of MNZ under sunlight radiation for 9 h. The results indicate that the alkaline cation has a predominant role in the photo-Fenton efficiency, as demonstrated by the superior degradation efficiencies of Na@giniite particles (91.2% and 72.5% with giniite concentration of 0.2 g L-1 and 0.07 g L-1, respectively), related with its high surface area (10.7 m2 g-1). Thus, it is demonstrated the suitability of Na@giniite particles as Fenton catalyst for MNZ removal from water.


Assuntos
Antibacterianos/análise , Compostos Férricos/química , Peróxido de Hidrogênio/química , Ferro/química , Metronidazol/análise , Poluentes Químicos da Água/análise , Antibacterianos/efeitos da radiação , Catálise , Metronidazol/efeitos da radiação , Oxirredução , Processos Fotoquímicos , Porosidade , Luz Solar , Propriedades de Superfície , Poluentes Químicos da Água/efeitos da radiação
19.
Eur Ann Allergy Clin Immunol ; 53(5): 214-220, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33182989

RESUMO

SUMMARY: Introduction. The Test for Respiratory and Asthma Control in Kids (TRACK) is a tool to assess asthma control in preschool children. This study aims to validate the Portuguese from Portugal version of the TRACK questionnaire. Methods. A prospective cohort study was carried out to assess their psychometric characteristics. Caregivers of 141 children under age 5 with asthma symptoms were enrolled. Results. Internal reliability was close to 0.70 (Cronbach's α). The test-retest reliability was 0.87. TRACK scores were different between well, partially, and non-controlled asthma groups (p less than 0.001). Patients rated as having better control showed an increase in TRACK scores. Conclusions. The Portuguese version of the TRACK questionnaire is accurate and reliable for monitoring asthma control. Its use may help to overcome challenges with the management of this age group.


Assuntos
Asma , Comparação Transcultural , Asma/diagnóstico , Pré-Escolar , Humanos , Portugal , Estudos Prospectivos , Reprodutibilidade dos Testes , Inquéritos e Questionários
20.
J. investig. allergol. clin. immunol ; 31(6): 471-480, 2021. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-216774

RESUMO

Background: Data on risk factors for uncontrolled asthma in preschool children are controversial. Objective: This study aims to explore the association between clinical and functional parameters and the lack of asthma control in preschool children. Methods: Children aged 3-5 years with asthma and healthy controls were recruited. A questionnaire was used to identify potential risk factors for uncontrolled asthma, as defined by the Global INitiative for Asthma criteria. Lung function and bronchial reversibility were evaluated through impulse oscillometry and spirometry. Adjusted odds ratios were estimated based on multivariable generalized additive regression models. The discriminative ability of the models was measured by the area under the receiver operating characteristic curve (AUC). Results: The study population comprised 121 children (107 with asthma and 14 healthy controls). Fifty-three patients (50%) had uncontrolled asthma. After adjustment, the variables associated with an increased risk of lack of control were as follows: “More than 3 flare-ups in the last 12 months”, “Moderate to severe rhinitis”, and “Relative variation in postbronchodilator FVC and FEV1”. The AUC of the final models that included variation in FVC or FEV1 were 0.82 and 0.81, respectively. The R5-20, R5-20%, and AX z-score values of the healthy group were lower than those of children with asthma. Conclusion: In preschool children, clinical and functional parameters are associated with uncontrolled asthma. More studies are needed to confirm the usefulness of impulse oscillometry (AU)


Antecedentes: Existe controversia sobre los factores de riesgo de asma no controlada en niños en edad preescolar. Objetivo: Este estudio tiene como objetivo explorar la asociación entre los parámetros clínicos y funcionales y la falta de control del asmaen niños en edad preescolar. Métodos: Se reclutaron niños de 3-5 años con asma y controles sanos. Se utilizó un cuestionario para identificar los posibles factores de riesgo de asma no controlada según lo definido por los criterios de la GINA (Global Initiative for Asthma [Iniciativa global para el asma]).La función pulmonar y la reversibilidad bronquial se evaluaron mediante oscilometría de impulsos (IOS) y espirometría. Los odds ratios ajustados (OR) se estimaron en base a modelos de regresión aditiva generalizada multivariable. La capacidad discriminativa de los modelos se midió por el área bajo la curva de características operativas del receptor (AUC). Resultados: Se incluyeron 121 niños, 107 de los cuales tenían asma y 14 eran controles sanos. Cincuenta y tres pacientes (50%) tenían asma no controlada. Después del ajuste, las variables asociadas con un mayor riesgo de falta de control fueron: "Más de 3 reagudizaciones en los últimos 12 meses", "rinitis moderada a grave"y "variación relativa en FVC y FEV1 después del broncodilatador". El AUC de los modelos finales que incluyeron variación de la FVC o FEV1 fueron 0,82 y 0,81, respectivamente. Los valores de R5-20, R5-20% y AX z-score del grupo sano fueron más bajos que los de los niños con asma. Conclusión: En niños en edad preescolar, los parámetros clínicos y funcionales están asociados con el asma no controlada. Se necesitan más estudios para confirmar la utilidad del IOS (AU)


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Asma/diagnóstico , Asma/prevenção & controle , Volume Expiratório Forçado , Testes de Função Respiratória , Oscilometria , Razão de Chances , Espirometria , Fatores de Risco , Estudos de Casos e Controles , Estudos Transversais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...